3.15 Regenerative Resistor Connection When the regenerative energy processing capacity is insufficient, connect an external regenerative resistor as required to set the regenerative resistor capacity (Pn012) and the regenerative resistor value (Pn013). 3.15.1 Connection of Regenerative Resistors The driver models 1R1A,1R7A,3R3A,500D,600D have no built-in regenerative resistor. When a regenerative resistor is externally connected, the resistor is connected to the B1/+ and B2 terminals. Refer to “A single-phase wiring diagram”. Or it is connected to the + and PB terminals. Refer to “E/F single-phase wiring diagram”.
In addition to 1R1A, 1R7A,3R3A,500D,600D the driver model has a built-in regenerative resistor. When the internal regenerative resistor does not meet the requirements, a regenerative resistor can be connected to remove the short wiring between the B2-B3 terminals and connect the external regenerative resistor to the driver. For B1/+, B2 terminals, refer to “B/C/D/E/F volume three-phase wiring diagram”. 3.15.2 Selection of Regenerative Resistor 66 SD700 Series Servo Technical Manual Mode Braking Voltage(V) Internal resistor Min. value of Max.
value of external resistor(Ω) external resistor(Ω) SD700-1R1A 380 / 40 400 SD700-1R7A / 40 200 SD700-3R3A / 40 100 SD700-5R5A 40Ω 60W 25 70 SD700-7R6A 40Ω 60W 15 50 SD700-9R5A 40Ω 60W 15 40 SD700-120A 30Ω 200W 10 30 SD700-160A 30Ω 200W 10 30 SD700-2R5D 700 80Ω 60W 80 225 SD700-3R8D 80Ω 60W 55 180 SD700-6R0D 40Ω 60W 35 110 SD700-8R4D 40Ω 60W 25 85 SD700-110D 40Ω 60W 25 70 SD700-170D 30Ω 100W 30 50 SD700-240D 30Ω 200W 15 40