Smart IP43 Charger 3. Insulation The insulation material and specifications effect the maximum temperature capability/rating (effecting current carrying capacity) and the maximum voltage isolation capability/rating of a cable. A. Temperature rating The insulation temperature rating effects the current carrying capacity of a cable and must not be exceeded when considering the combination of a) maximum ambient temperature, b) the installation environment (which effects the dissipation of heat), and c) temperature rise due the heat generated by the cable when operating at the fuse or circuit breaker current rating.
To prevent overheating of the cable insulation, use high quality flexible DC power cabling with an insulation temperature rating of at least 90°/194°F (preferably 105°C/221°F), or as required for the installation. B. Voltage rating To ensure robust electrical isolation and overall safety, use high quality flexible DC power cabling with an insulation voltage rating that exceeds the maximum operating voltage of the system; high quality flexible DC power cabling typically has an insulation voltage rating of 0.6/1kV.
Refer to the table below for the minimum DC power cable size/gauge (cross sectional area) recommended for each Smart IP43 Charger model, and the installation specific DC power cable length: The DC power cable length ranges represent one way length between charger and battery, the total circuit length (positive and negative cable length) has been assumed to be double one way length for the voltage drop calculations. Certain combinations are "Not recommended" as voltage drop would be excessive even with the largest compatible DC power cable size; in addition to high power loss, excessive voltage drop can cause charging issues.
The DC power cable size/gauge recommendations above are based on cabling with an insulation rating of at least 90°C (194°F) routed within an unenclosed area at 30°C (86°F) ambient temperature and not bundled with other cabling, and a 3% maximum voltage drop limit; these recommendations are generic and do not cover the intricacies of all installations and/or cable types, please consult a certified installer for guidance with specific and/or complex installations. 5.2.2. Remote on/off The Smart IP43 Charger is equipped with remote on/off terminals, these terminals enable charging to be turned on or off remotely dependent on their state.
There are 3 options to turn the Smart IP43 Charger on using the remote terminal(s): 1. Interconnect / short the L and H terminals (factory default is a shorting link between L and H). The L and H terminal can be interconnected /shorted via a switch, relay or other external device, like a battery management system (BMS). 2. Pull the H terminal to a high voltage level; when the voltage on the H terminal is above 2.9V (connected to battery positive for example) the charger will turn on. The H terminal can be connected to a high voltage level via a switch, relay or other external device, like a battery management system (BMS). 3.
Pull the L terminal to a low voltage level; when the voltage on the L terminal is below 3.5V (connected to battery negative for example) the charger will turn off. The L terminal can be connected to a low voltage level via a switch, relay or other external device, like a battery management system (BMS). To turn the Smart IP43 Charger off using the remote terminal(s), both terminals need to have an open circuit relative to each other and be left floating (no connection to a high or low voltage level).
Page 19 Installation Charger Max Minimum cable size/gauge model current 1.5 to 3.0m 3.0 to 4.5m 4.5 to 6.0m 12/30 30A 10mm2 | 8 AWG 10mm2 | 8 AWG 16mm2 | 6 AWG Not recommended 12/50 50A 16mm2 | 6 AWG 16mm2 | 6 AWG Not recommended Not recommended 24/16 16A 4mm2 | 12 AWG 4mm2 | 12 AWG 4mm2 | 12 AWG 6mm2 | 10 AWG 24/25 25A 6mm2 | 10 AWG 6mm2 | 10 AWG 10mm2 | 8 AWG 10mm2 | 8 AWG 36/15 15A 4mm2 | 12 AWG 4mm2 | 12 AWG 4mm2 | 12 AWG 6mm2 | 10 AWG 48/13 13A 4mm2 | 12 AWG 4mm2 | 12 AWG 4mm2 | 12 AWG 6mm2 | 10 AWG