Smart IP43 Charger Manufacturer IP43 — 5.2.3. Programmable relay

Smart IP43 Charger 5.2.3. Programmable relay The Smart IP43 Charger is equipped with a programmable relay, the relay can be used for external control based on the selected relay mode (Alarm, Remote control, or Charging) and operational conditions. There are 3 programmable relay terminals: 1. NO (Normally open) 2. C (Common) 3. NC (Normally closed) When the relay is switched off there is a closed circuit between C and NC, and an open circuit between C an NO. When the relay is switched on there is a closed circuit between C and NO, and an open circuit between C an NC. Wire the relay terminals to an external device as necessary in order to achieve the desired signal/control. Note:

The programmable relay function only works when AC input power is available and charging is enabled. If charging is disabled by any means (the remote on/off terminals, via VictronConnect or a GX device) the programmable relay functionally will also be disabled. Page 20 Installation