Smart IP43 Charger Manufacturer IP43 — 6.2. Setup using VictronConnect

Smart IP43 Charger 11. Select the most appropriate integrated charge mode (Normal, Normal + Recondition, High, High + Recondition or Li-ion) from the Built-in presets menu, then select OK . Ensure that recondition stage is only enabled when required, as unnecessary or overuse will reduce battery life. 12. If the maximum rated charge current is excessive, enable low current mode (charge current limited to 50% of the maximum rated charge current) or minimum current mode (charge current limited to 25% of the maximum rated charge current). To enable (or disable) low current mode: a. Select Maximum charge current to access the Maximum charge current pop-up dialog box. b.

Select the most appropriate maximum charge current from the preset options (Minimum / Low / Maximum), or specify an alternative current (between the minimum and maximum limits) using the numeric input controls near the bottom. Page 31 Setup