Check for deflection Eurocode 2 has two alternative methods of designing for deflection; either by limiting span-to-depth ratio or by assessing the theoretical deflection using the Expressions given in the Eurocode. In this we have to find using span to depth ratio. Procedure for finding deflection 1. Determine basic l/d from below fig 2. Determine Factor 1 (F1) For ribbed or waffle slabs F1 = 1 0.1 ((bf/bw) 1) ≥ 0.8 Where bf = flange breadth and bw= rib breadth Otherwise F1 = 1.0 3. Determine Factor 2 (F2) Where the slab span exceeds 7 m and it supports brittle partitions, F2 = 7/ l eff Otherwise F2 = 1.0 4.
Determine Factor 3 (F3) F3 = 310/ss Where ss = Stress in reinforcement at serviceability limit state or ss may be assumed to be 310 MPa (i.e. F3 = 1.0) Check A s,prov ≤ 1.5 A s,req’d Is basic l / d * F1 * F2 *F3 ≥ Actual l / d if this condition is satisfied it is safe from deflection otherwise we have to increase A s,prov. 33