Punching shear The design value of the punching shear force, V Ed, will usually be the support reaction at the ultimate limit state. 1. The maximum value of shear at the column face is not limited to 5 MPa, and depends on the concrete strength used. 2. The control perimeters for rectangular columns in this have rounded corners. 3. Where shear reinforcement is required the procedure is simpler; the point at which no shear reinforcement is required can be calculated directly and then used to determine the extent of the area over which shear reinforcement is required. 4. It is assumed that the reinforcement will be in a radial arrangement.
However, the reinforcement can be laid on a grid provided the spacing rules are followed. Procedure for determining the punching shear 1. Determine value of factor β from the below fig 2. Determine value of v Ed,max design shear stress at face of column from vEd,max = β VEd /(ui deff) where ui is perimeter of column deff = (dy + dz)/2 (dy and dzare the effective depths in orthogonal dire ctions) Determine value of vRd,max from Table 1 Check v Ed,max v Rd,max if not redesign the slab.
Determine value of vEd, (design shear stress) vEd,max = β VEd /(ui deff) where u1 is length of control perimeter Determine concrete punching shear capacity (without shear reinforcement), vRD,c from where rl = (rly rlz)0.5 (rly, rlz are the reinforcement ratios in two orthogonal directions for fully bonded tension steel, taken over a width equal to column width plus 3 d each side.) Is vEd > vRd,c if it satisfies Punching shear reinforcement not required otherwise 34