SPRUT — ANALYSIS AND DESIGN OF FLAT SLABS USING VARIOUS CODES

For negative moment in middle strip: 3 24.6 10 R 50.311 324 14.76 32.4 u M b Reinforcement ratio = 0.0013 Area of reinforcement = 0.0013x 14.76 x 6 x 12 = 1.38 2 / in ft Provide Bar No. 6, at a spacing of 4 in, 3 in number For positive moment in middle strip: 3 20.75 10 R 43.40 324 14.76 32.4 u M b Reinforcement ratio = 0.00075 Area of reinforcement = 0.00075x 14.76 x 6 x 12 = 0.79 2 / in ft Provide Bar No. 4, at a spacing of 3 in, 4 in number Calculation of area of steel: Along longer span: For negative moment in column strip:

3 115.50 10 R 219.77 324 16.22 32.4 u M b Reinforcement ratio = 0.00375 Area of reinforcement = 0.00375 x 16.22 x 6 x 12 = 4.38 2 / in ft Provide Bar No.11, at a spacing of 4 in, 8 in number For positive moment in column strip : 3 49.8 10 R 94.76 324 16.22 32.4 u M b Reinforcement ratio = 0.00175 Area of reinforcement = 0.00175 x 16.22 x 6 x 12 = 2.04 2 / in ft 49