Supermicro A+ Server 1012G-MTF — Supermicro A+ Server 1012G-MTF User's Manual (1U Rackmount Server) PDF

A+ SERVER 1012G-MTF USER'S MANUAL 3-3 Control Panel LEDs The control panel located on the front of the SC813MTS-350CBP chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Information LED Alerts operator of several states, as noted in the table below. 2 NIC2 Indicates network activity on GLAN2 when flashing. 1 NIC1 Indicates network activity on GLAN1 when flashing. 3-2 Information LED Status Description Continuously on and red An overheat condition has occured.

(This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan. Blinking red (0.25Hz) Power failure, check for a non-operational power supply. Solid blue Local UID has been activated. Use this function to locate the server in a rack mount environment. Blinking blue Remote UID is on. Use this function to identify the server from a remote location.