A+ Server 1122GG-TF User's Manual System Fan Failure Fan speed is controlled by system temperature by means of a BIOS setting. If a fan fails, the remaining fans will ramp up to full speed. The system can continue to run with a failed fan. Replace any failed fan at your earliest convenience with the same type and model. Replacing a System Fan 1. If the BIOS is not being utilized to determine which fan has failed, open the top cover of the chassis while the system is running to locate the position of the failed fan. Never run the server for an extended period of time with the top cover open. 2. Turn off the power to the system and unplug the system from the outlet. 3.

Remove the failed fan's power cable from the backplane. 4. Remove the four pins securing the fan to the fan housing. 5. Lift the failed fan from the fan housing and out of the chassis. 6. Place the new fan into the vacant space in the fan housing, while making sure the arrows on the top of the fan (indicating air direction) point in the same direc­ tion as the arrows on the other fans in the same fan housing. 7. Reconnect the fan wires to the exact same chassis fan headers as the previ­ ous fan. 8. Power up the system and check that the fan is working properly before replac­ ing the chassis cover. Figure 6-13. Removing a Fan from the Fan Housing 6-14