Supermicro SuperServer 1019P-WTR — Checking the Airflow

SuperServer 1019P-WTR User's Manual Chapter 3: Maintenance and Component Installation Caution: Use caution when working around the hard drive backplane. Do not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes, which aid in proper airflow. Caution: Regardless of how many hard drives are installed, all drive carriers must remain in the drive bays to maintain proper airflow. System Cooling Up to six 4-cm counter-rotating fans provide the cooling for the system. Each fan unit is actually made up of two fans joined back-to-back, which rotate in opposite directions.

This counter-rotating action generates exceptional airflow and is effective in dampening vibration levels. The chassis provides two additional open fan housings, where an additional system fan may be added for optimal cooling. It is very important that the chassis top cover is installed for the cooling air to circulate properly through the chassis and cool the components. Installing Fans The SC116 chassis includes five pre-installed fans. One additional open slot is available so that one more fan may be added if additional cooling is required. These fans are NOT redundant, hot-plug, and so must be replaced when they fail. Figure 3-6.

Replacing a System Fan Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fans will ramp up to full speed. Replace any failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan). Note: The figure above is intended to show the Fan locations only. The serverboard and chassis may differ from that found in the 1019P-WTR. Checking the Airflow 1. Open the chassis while the system is running to determine which fan has failed. Never run the server for an extended period of time with the chassis open. Check the Airflow 1. Make sure there are no objects obstructing the airflow in and out of the server.

In addition, if you are using a front bezel, make sure the bezel's filter is replaced periodically. 2. Turn off the power to the system and unplug the power cord from the power supply. 3. Remove the failed fan's wiring from the fan header on the serverboard. 2. Do not operate the server without hard drives or drive carriers in the drive bays. Use only recommended server parts. 4. Lift the failed fan from the chassis and pull it completely out. 5. Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan (indicating air direction) point in the same direction as the arrows on the other fans. 3.

Make sure no wires or foreign objects obstruct airflow through the chassis. Pull all excess cabling out of the airflow path or use shorter cables. 4. The control panel LEDs inform you of system status. See Chapter 4 System Interface for details on the LEDs and the control panel buttons. 6. Reconnect the fan wires to the same chassis fan header as the previous fan. 7. Power up the system and check that the fan is working properly before replacing the chassis cover. 43 42 3