Supermicro SuperServer 1019P-WTR — Power Supply Failure

SuperServer 1019P-WTR User's Manual Chapter 3: Maintenance and Component Installation Power Supply The SC116 chassis comes equipped with two redundant 500 Watts, hot-plug power supplies. These power supplies are auto-switching capable and automatically sense and operate at a 100v to 240v input voltage. An amber light will be illuminated on the power supply when the power is off. An illuminated green light indicates that the power supply is operating. The SC116 chassis comes equipped with two redundant 500 Watts, hot-plug power supplies. These power supplies are auto-switching capable and automatically sense and operate at a 100v to 240v input voltage.

An amber light will be illuminated on the power supply when the power is off. An illuminated green light indicates that the power supply is operating. Power Supply Failure The SC116 chassis includes a redundant power supply, which allows the server to continue running when one power supply has been removed. Replacement units can be ordered directly from Supermicro. Replacing the Power Supply 1. Unplug the AC power cord from the failed power supply module (with the RED LED lit up). 2. Push the release tab (on the back of the power supply) as illustrated, then pull the power supply out using the handle provided. Release Tab Figure 3-7. Removing/Replacing a Power Supply 3.

Push the new power supply module into the power bay until you hear a click (replace with the same model). Note: The figures above is intended to show the power supply locations only. The chassis and serverboard may differ from that found in the 1019P-WTR. 4. Reconnect the power cord to the new module and make sure the GREEN LED is lit up and the power supply fans are rotating.. 45 44