S UPER S ERVER 1027B-MTF User's Manual NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on Pins 9 and 10. NIC1 LED and NIC2 LED are 2-pin NIC LED headers. Attach NIC LED cables to NIC1 LED and NIC2 LED to display network activities for LAN 1 and LAN2. Refer to the table on the right for pin defi nitions. Overheat (OH)/Fan Fail/Front UID LED Connect an LED cable to the Front UID and OH/Fan Fail connections on pins 7 and 8 of JF1. The red LED on pin 7 provides warnings of overheat, fan fail- ure or power failure.
The blue LED on pin 8 works as the front panel UID LED indicator. The red LED takes precedence over the blue LED by default. Refer to the table on the right for pin defi nitions. Reset Button The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a the hardware Reset Button on the computer case. Refer to the table on the right for pin defi nitions. Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin defi nitions.
5-14 LAN1/LAN2 LED Pin Defi nitions (JF1) Pin# Defi nition 9/11 Vcc 10/12 Ground OH/Fan Fail/ PWR Fail/Blue UID _ LED Pin Defi nitions (JF1) Pin# Defi nition 7 Red LED-Cathode/OH/Fan Fail/ _ Power Fail5.5V.SB 8 Blue UID LED _ OH/Fan Fail Indicator Status State Defi nition Off Normal On Overheat Flashing Fan Fail Reset Button Pin Defi nitions (JF1) Pin# Defi nition 3 Reset 4 Ground PWR Fail LED Pin Defi nitions (JF1) Pin# Defi nition 5 Vcc 6 Ground