Chapter 6: Advanced Chassis Setup In the 2U Twin, each node (serverboard) controls the two fans that reside on its side of the chassis. In the event that one of the serverboard drawers is removed, then the remaining node/serverboard will operate all four fans. Fan Confi guration Note: Due to this confi guration, the node on the same side of the chassis as the failed fan must be powered down before replacing the fan. System Fan Failure If a fan fails, the remaining fans will ramp up to full speed and the overheat/fan fail LED on the control panel will blink on and off (about once per second). Replace any failed fan at your earliest convenience with the same type and model.

See note above about powering down the node associated with the failed fan befi re replacing. Changing a System Fan If necessary, open the chassis while the power is running to determine which 1. fan has failed. (Never run the server for an extended period of time with the chassis cover open.) Remove the failed fan's wiring from the backplane. 2. Lift the fan up and out of the chassis. 3. Place the replacement fan into the vacant space in the housing while making 4. sure the arrows on the top of the fan (indicating air direction) point in the same direction as the arrows on the other fans. Confi rm that the fan is working properly before replacing the chassis cover. 5. 6-3