Supermicro SuperServer 5019S-ML — Installing with a Rackmount Kit

SuperServer 5019S-ML User's Manual Chapter 2: Server Installation Circuit Overloading The rack hardware includes two assemblies that consists of two sections: an inner rail that secures to the chassis and an outer rail that secures directly to the rack itself (see Figure 2-1). Installing the Chassis Rails Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. 1.

Detach the two rail sections from each other by depressing the locking tab on the inner rail to release it from its locked position, then pull the two rails completely apart. Reliable Ground 2. Repeat step 1 for the remaining rail assembly. A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.). 3. Position the fixed chassis rail sections you just removed along the side of the chassis making sure the three screw holes line up. Note that the rails are left/right side specific. 4.

Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack. To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position.

Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing. This unit should be mounted at the bottom of the rack if it is the only unit in the rack. When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. 2.3 Installing the System Into a Rack This section provides information on installing the SuperServer 5018D-MF into a rack. Note:

the server may be installed as is - rack hardware is optional. Basic Installation Procedure The 5019S-ML server has two rack mounting "ear" brackets, which are located on each side of the front of the chassis. To mount the system into a rack, simply screw these brackets directly to the front of the rack (two screws for each bracket). Figure 2-1. Identifying the Sections of the Rack Rails Installing with a Rackmount Kit Slide rail mounted equipment is not to be used as a shelf or a work space. This is a guideline for installing the unit into a rack with the optional rack kit (MCP-290-00004- 03). You should also refer to the installation instructions that came with the rack unit you are using.

Be aware that there are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. Warning: do not pick up the server with the front handles. They are designed to pull the system from a rack only. 20 19