Supermicro SuperServer 5019S-ML — 6.5 IPMI

SuperServer 5019S-ML User's Manual Chapter 6: BIOS When Log is Full The following IPMI information will be displayed: IPMI Firmware Revision Select Erase Immediately to immediately erase all errors in the SMBIOS event log when the event log is full. Select Do Nothing for the system to do nothing when the SMBIOS event log is full. The options are Do Nothing and Erase Immediately. IPMI Status SMBIOS Event Log Standard Settings System Event Log Log System Boot Event Select Enabled to log system boot events. The options are Disabled and Enabled. Enabling/Disabling Options MECI (Multiple Event Count Increment) SEL Components Enter the increment value for the multiple event counter.

Enter a number between 1 to 255. The default setting is 1 . Select Enabled to enable all system event logging support at bootup. The options are Enabled and Disabled. METW (Multiple Event Count Time Window) Erasing Settings This item is used to determine how long (in minutes) the multiple event counter should wait before generating a new event log. Enter a number between 0 to 99. The default setting is 60 . Erase SEL Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot.

The options are No, Yes, On next reset, and Yes, On every reset. Note : Please reboot the system for the changes to take effect. View SMBIOS Event Log This item allows the user to view the event in the SMBIOS event log. The following categories are displayed: When SEL is Full Date/Time/Error Code/Severity This feature allows the user to determine what the AMI BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately. 6.5 IPMI Note : After making changes on a setting, be sure to reboot the system for the changes to take effect.

This submenu allows the user to configure Intelligent Platform Management Interface (IPMI) settings. BMC Network Configuration The following items will be displayed: IPMI LAN Selection IPMI Network Link Status Update IPMI LAN Configuration Select Yes for the system BIOS to automatically reset the following IPMI settings upon next system boot. The options are Yes and No . 87 86