Chapter 2: Server Installation The SC827HQ+ chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached to the chassis, and do not interfere with normal use of the chassis if you decide not to use a server rack. The inner rail extension is attached to the inner rail to mount the chassis in the rack. Installing the Inner Rail Extension Installing the Inner Rails (Figure 2-2) 1. Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes. Make sure the extension faces "outward" just like the pre-attached inner rail. 2.
Slide the extension toward the front of the chassis. 3. Secure the chassis with 2 screws as illustrated. Repeat steps for the other inner rail extension. Figure 2-2. Installing the Inner Rail Extensions 1 3 1 2 1 3 1 1 Slide rail mounted equipment is not to be used as a shelf or a work space. Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over. 2-5