Supermicro 5038MD-H8TRF — Supermicro SuperServer 5038MD-H8TRF User's Manual (Revision 1.0) PDF

SuperServer 5038MD-H8TRF User's Manual Power Supply The chassis features redundant power supplies. They are hot-swappable, meaning they can be changed without powering down the system. New units can be ordered directly from Supermicro or authorized distributors. These power supplies are auto-switching capable. This feature enables them to automatically sense the input voltage and operate at a 100-120v or 180-240v. An amber light will be illuminated on the power supply when the power is off. An illuminated green light indicates that the power supply is operating. Changing the Power Supply 1. With the system running, unplug the AC power cord that provides power to the failed module. 2.

Press and hold the release tab on the front, top of the power module. 3. Grasp the handle and pull the power supply out of its bay. 4. Push the replacement power supply module into the empty bay until it clicks into the locked position. 5. Plug the AC power cord back into the power supply module. Release Tab Figure 3-12. Replacing a Power Supply Module 42