Chapter 5: Advanced Motherboard Setup Fan Fail LED (FFL) The Fan Fail LED connection is lo- cated on pins 2 and 4 of JF1. See Table 5-4 for pin definitions and Figure 5-2 for pin locations. Table 5-4 Fan Fail LED Pin Definitions (JF1) IDE LED Table 5-5 IDE_LED Pin Definitions (JF1) The IDE Drive LED connection is located on pins 7 and 9 of JF1. This will send an indication of IDE disk activity to the front control panel. See Table 5-5 for pin defi- nitions and Figure 5-2 for pin loca- tions. Power Fail LED (PFL) Table 5-6 Power Fail LED Pin Definitions (JF1) The Power Fail LED connection is located on pins 8 and 10 of JF1. See Table 5-6 for pin definitions and Figure 5-2 for pin locations.
PWR_ON The PWR_ON connection is lo- cated on pins 11 and 13 of JF1. Momentarily contacting both pins will power on/off the system (based on the power management scheme of your operating sys- tem). See Table 5-7 for pin defini- tions and Figure 5-2 for pin loca- tions. Table 5-7 PWR_ON Connector Pin Definitions (JF1) NIC_LED Table 5-8 NIC_LED Pin Definitions (JF1) The Network Interface Controller LED connection is located on pins 12 and 14 of JF1. This header is used to display network activity. See Table 5-8 for pin definitions and Figure 5-2 for pin locations.
5-13 Pin Number Definition 4 6 +5V Fan Fail Pin Number Definition 7 9 +5V HD Active Pin Number Definition 8 10 +5V PWR Fail Pin Number Definition 11 13 P W O N _ Ground Pin Number Definition 12 14 +5V NIC Active