S UPER S ERVER 6040 Manual Power Supply Fail Header (For Supermciro's Triple Redundant Power Supplies only) Table 5-20 PWR P Header Pin Definitions A four-pin connector from the power supply connects to the PWR Supply Fail header (labelled JP 54) on the motherboard to no- tify you in the event of a power supply failure. If your system does not have three power supply units, you should disable this with JP54 to prevent false alarms. See Table 5-20 for the pin definitions of the PWR P header. (The power supplies are numbered from top to bottom.) SLED (SCSI LED) Indicator Table 5-21 SLED (SCSI LED) Pin Definitions The SLED connector is used to pro- vide an LED indication of SCSI ac- tivity.
Refer to Table 5-21 for con- necting the SCSI LED. 5-8 DIP Switch Settings Table 5-22 CPU Core/Bus Ratio Selection (DIP Switch1) DIP Switch 1: Core/Bus Ratio The red "DIP" Switch labeled SW1 is located on the 370DE6. SW1 has four individual switches which are used to set the core/bus ration. The example on the right will Ratio to use. The general rule is to divide the CPU speed by the bus speed (100 MHz for the 370DE6). If you have a 550 MHz CPU, divid- ing it by 100 will give you a CPU show you which CPU Core/Bus 550 MHz = 100 MHz x 5.5 CPU Speed = Bus Freq.
x Ratio 5-18 Pin Number Definition 1 2 3 4 P/S1 signal P/S2 signal P/S3 signal Reset Pin Number Definition 1 2 3 4 Positive Negative Negative Positive C P U S W 1 #4 S W 1 #3 S W 1 #2 S W 1 #1 400-533 450-600 500-666 550-733 600-800 650-866 700-933 750-1000 800-1064 850-1130 900-1200 O N O N O N O N O F F O F F O F F O F F O F F O F F O F F O F F O F F O F F O F F O N O N O N O N O F F O F F O F F O N O N O F F O F F O N O N O F F O F F O N O N O F F O N O F F O N O F F O N O F F O N O F F O N O F F O N