SUPERSERVER 8048B-TRFT USER'S MANUAL Unit Identifier Switch/LED A Unit Identifier (UID) switch on the AOM-X10QBi-A I/O module, and two LED indicators are located on the baseboard. The UID switch is located next to the LAN ports on the I/O module. The rear UID LED (LED28) is located next to the UID switch. The front panel UID LED is located at pins 7/8 of the Front Control Panel at JF1. Connect a cable to pins 7/8 on JF1 for front panel UID LED indication. When you press the UID switch, both rear UID LED and front panel UID LED indicators will be turned on. Press the UID switch again to turn off both LED indicators.

These UID indicators provide easy identification of a system unit that may be in need of service. Note: UID can also be triggered via the IPMI on the system serverboard. For more information on the IPMI, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com. Serial Ports COM1 is located on the AOM-X10QBi-A I/O module. COM2 is located on the X10QBi baseboard to provide front- accessible serial support. See the table on the right for pin definitions. Video Connectors Two video (VGA) ports are located on the AOM-X10QBi-A I/O module. Refer to Section 5-6 for locations.

5-22 UID Switch Pin# Definition 1 Ground 2 Ground 3 Button In 4 Ground UID LED Status Color/State OS Status Blue: On Windows OS Unit Identified Blue: Blinking Linux OS Unit Identified Serial COM) Ports Pin Definitions Pin # Definition Pin # Definition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 N/A