Supermicro SuperServer 8060 — Supermicro SuperServer 8060 User Manual PDF – 4U Quad Xeon Server Guide

S UPER S ERVER 8060 Manual Replacing System Exhaust Fans 1. Removing a hot-plug fan housing: With the chassis cover removed, first unplug the fan cable corresponding to the failed fan. Next, push down on the locking tabs at the top and bottom of the fan housing, which protrude through the back end of the chassis. This will detach the housing from the chassis. Reach inside the chassis and pull the housing out of its hole in the chassis. Unscrew the four screws that hold the fan in the housing to remove the bad fan. 2. Installing a new system fan: Replace the failed fan with an identical 9-cm, 12 volt fan (available from Supermicro).

After the new fan has been inserted, reassemble the fan housing. To put it back in the chassis, first insert the bottom fan housing tab into its hole, then swing the top of the fan toward the chassis, pushing down on the top fan housing tab to insert it into the correspond- ing hole in the chassis. You should hear it click into place when fully inserted. Finish by plugging the fan cable back into the power connector you detached it from. Check that the fan is working properly and that the LEDs on the control panel circuit board (Figure 6-2) and the front control panel have turned off. Finish by replacing the top panel of the chassis.

6-4 Drive Bay Installation/Removal Accessing the Drive Bays SCSI Drives: You do not need to access the inside of the chassis to replace or swap SCSI drives. Proceed to the next step for instructions. Note: You must use standard 1" high, 80-pin SCA SCSI drives in the SuperServer 8060. CD-ROM/Floppy Disk Drive: For installing/removing the CD-ROM or floppy disk drive, you will need to gain access to the inside of the 8060 by removing the top cover of the chassis. Proceed to the "CD-ROM and Floppy Drive Installation" section later in this chapter for instructions. Note: Only a "slim" CD-ROM drive will fit in the 8060. 6-6