SuperStorageSystem 5029P-E1CTR12L User's Manual 2.3 Installing the Server into a Rack This section provides information on installing the SC826 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using. Separating the Sections of the Rack Rails The SC826BE1C chassis includes two rail assemblies in the rack mounting kit. Each assembly consists of two sections:
an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself. Installing the Inner Rail Extension The inner rails are pre-attached to the chassis, and do not interfere with normal use of the chassis if you decide not to use a server rack. The inner rail extension is attached to the inner rail to mount the chassis in the rack. Installing the Inner Rails 1. Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes. Make sure the extension faces "outward" just like the pre-attached inner rail. 2. Slide the extension toward the front of the chassis. 3.
Secure the chassis with 2 screws as illustrated. Repeat steps for the other inner rail extension. Rail Assembly 1 Separating the Inner and Outer Rails 1. Locate the rail assembly in the chassis packaging. 2 Extending the Rails 2. Extend the rail assembly by pulling it outward. 3 3. Press the quick-release tab. Quick Release Tab 4 4. Separate the inner rail extension from the outer rail assembly. Separating the Inner Rail Extensions Figure 2-1. Identifying the Rail Sections 20