Supermicro 5029P-E1CTR12L — Supermicro SuperStorage 5029P-E1CTR12L User's Manual PDF Download

Chapter 2: Server Installation Installing the Server into a Telco Rack To install the SuperServer 5029P-E1CTR12L into a Telco (or “open”) type rack, use two L-shaped brackets on either side of the chassis (four total). 1. First, determine how far the server will extend out from the front of the rack. The chassis should be positioned so that the weight is balanced between front and back. 2. Attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the rack. 3. Finish by sliding the chassis into the rack and tightening the brackets to the rack. See Figure 2-4. Figure 2-4.

Installing the Server into a Telco Rack Note: Figure is for illustrative purposes only. Always install servers to the bottom of a rack first. 23