SuperStorageSystem 5029P-E1CTR12L User's Manual Figure 3-5. Mounting a Drive in a Carrier Caution: Except for short periods of time, do not operate the server without the chassis cover in place. The cover must be in place to allow proper airflow and prevent overheating. Hard Drive Backplane The hard drives plug into a backplane that provides power, drive ID and bus termination. The supplied RAID controller provides hot-swap capability with drive state indication. The backplane is already preconfigured, so no jumper or switch configurations are required. System Cooling Three 8-cm counter-rotating fans provide the cooling for the system.
Installing Fans Fan speed is controlled by system temperature via BIOS. If a fan fails, the remaining fans will ramp up to full speed. Replace any failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan). 1. With the server powered on, remove the top chassis cover as described in Section 3.2 and inspect the fans to see which one has failed. 2. Remove power from the system as described in Section 3.1. 3. Press the fan release tab to lift the failed fan from the chassis and pull it completely from the chassis. 4.
Place the new fan into the vacant space in the housing, while making sure the arrows on the top of the fan (indicating air direction) point in the same direction as the arrows on the other fans. 5. Power up the system and check that the fan is working properly before replacing the chassis cover. 36