SuperStorageSystem 5049P-E1CTR36L User's Manual Installing One 3.5" HDD Installing Two 2.5" HDDs Installing the Bracket onto the Chassis Figure 3-6. Installing Optional Fixed Hard Drives System Cooling Seven 8-cm hot-swap fans provide the cooling for the system. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components. System Fan Failure Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fans will ramp up to full speed.
Replace any failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan). Installing Fans 1. Depress the tab on the side of the fan to unlock and remove the fan along with its housing. The fan's power connections will automatically detach. 2. System power does not need to be shut down since the fans are hot-pluggable. 3. Replace the failed fan with an identical 8-cm, 12 volt fan (available from Supermicro). 4. Position the new fan into the space vacated by the failed fan previously removed. A "click" can be heard when the fan is fully installed in place and the power connections are made. 5.
If the system power is on, the hot-plug feature will cause the fan to start immediately upon being connected to its header on the serverboard. 39