S uper W orkstation 7045A-WT User's Manual CMOS Clear JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To clear CMOS, First power down the system and unplug the power cord(s). 1. With the power disconnected, short the CMOS pads with a metal object such 2. as a small screwdriver. Remove the screwdriver (or shorting device). 3. Reconnect the power cord(s) and power on the system. 4. Note: Do not use the PW_ON connector to clear CMOS. LAN1/2 Enable/Disable Change the setting of jumper JPL1 to enable or disable the LAN1/LAN2 Eth- ernets port on the serverboard.
See the table on the right for jumper settings. The default setting is enabled. 3rd Power Fail Detect The system can notify you in the event of a power supply failure. This feature is available when three power supply units are installed in the chassis with one acting as a backup. If you only have one or two power supply units installed, you should disable this detection feature (the default setting) with J3P to prevent false alarms. 5-22 LAN1/2 Enable/Disable Jumper Settings (JPL1) Jumper Setting Defi nition Pins 1-2 Enabled Pins 2-3 Disabled 3rd Power Fail Detect Jumper Settings (J3P) Jumper Setting Defi nition Closed Enabled Open Disabled