Chapter 5: Advanced Serverboard Setup Installation and Removal of the Heatsink Installing the Heatsink Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied 1. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the retention mechanism. 2. Screw in two diagonal screws until just snug. Do not over- tighten the screws, which may damage the CPU.) 3. Fully tighten all four screws. Removing the Heatsink Note: We do not recommend removing the CPU or the heatsink. If you do need to remove the heatsink, please follow the instructions below to prevent damage to the CPU or the CPU socket. 1.

Unplug the power cord from the power supply. 2. Unscrew and remove the heatsink screws, starting by loosening each a little at a time. 3. Hold the heatsink and gently wriggle it to loosen it from the CPU. (Do not use excessive force!) 4. Once the heatsink is loosened, remove it from the CPU. 5. Clean the surface of the CPU and the heatsink to get rid of the old thermal grease. Reapply the proper amount of thermal grease before re-installing the heatsink. 5-7