Chapter 6: Advanced Chassis Setup 6-5 Power Supply This chassis features an auto-switching power supply. This enables it to automatically sense and operate at a 100v to 240v input voltage. An amber light will be illuminated when the power is off. An green light indicates that the power supply is operating. Replacing the Power Supply With a redundant power supply, the system automatically switches to the second power supply if the first should fail. Replacing the Power Supply 1. The power cords attach in the rear of the chassis. Remove the cord that corresponds to the module to be replaced. 2. On the front of the chassis, push the release button on the power supply module. (Figure 6-21) 3.

Pull the power supply out using the handle provided. 4. Replace the failed power module with the same model. Push the new module into the power bay until you hear a click. 5. Replace the AC power cord. Release Button Figure 6-21. Power Supply Release Button 6-19