Overview TwinCAT IEC61131-3 programming based on a manufacturer-independent standard TwinCAT PLC Server: up to 4 PLCs on one PC The PLC server processes programs at fixed cycle times. TwinCAT starts the tasks of the run time systems in a deterministic fashion, i.e. up to 4 PLC run time systems can be run simultaneously on one PC. The run time systems, in turn, have multitasking abilities with 4 tasks each. Therefore, the PLC server offers 16 tasks in 4 run time systems, each task with its own priority and cycle time. In total, up to 32 Mbytes of program and 4 Mbytes of data can be used. The execution time on PC processors is extremely fast. I/O data is organized by the System Manager.
Start and stop behavior are identical to that of a "hardware" PLC (which, as we know, is also operated with software). PLC booting on PC startup and remanent data are supported; while Windows NT is executing a user change, the PLC continues to operate. TwinCAT NC PTP and NC I axis control PTP on a PC The NC server processes the motion control tasks for positioning of switched motors, stepper motors, frequency-controlled (FU) motors and servo-controlled (servo) motors. All widespread kinds of drive amplifiers (servo, FU, stepper motor controllers) and contactors can be integrated via the known interfaces. Position detection is absolute, incremental, by encoder or via the drive.
The controller characteristic is defined precisely by way of the acceleration, deceleration, and jerk: fine adjustment of the trapezoidal profile of PTP positioning is possible. Commissioning is supported by online menus and measurement tools help to determine the following error, for instance. Contouring control to DIN66025 TwinCAT System Manager links the world with TwinCAT System Concept 9 Version: 1.0 Icon Description "TwinCAT PLC Control" is the programming environment for the PLC (PLC server) in the system: a powerful 32-bit programming environment for programs whose code size and data areas far exceed the possibilities of conventional PLC systems.
TwinCAT PLC offers all languages defined in the IEC61131-3 standard. The programming environment makes it easy for programmers of conventional PLC systems to become acquainted with IEC61131-3 using support tools. Its "object- oriented" structure suppresses side effects during analysis (online status display). Program and data changes are executed online in any code and the detection and remedying of errors (debugging) are supported with a very powerful link to the run time systems (servers) which, incidentally, is also network compatible. Programs are compiled for PC and additionally for a number of mini-PLC-hardware. All usual characteristics of a PLC are available.
Icon Description Contouring control tasks are executed in groups of 3 drives in space. They are defined and run in conformity with DIN66025.They are integrated in the PLC in a form that is similar to plain language, i.e. by using function blocks: drive control is integrated in IEC61131-3.Up to 256 axes (depending only on the PC processor used) can be moved simultaneously. Thanks to PC technology, TwinCAT's performance capabilities are constantly increasing. Icon Description The System Manger is the system's configuration centre. The number and programs of the PLC systems, configuration of axis control and the connected I/O channels are related to one another.
The System Manager links all system components and their data relations with one another, and data areas and process images are exchanged synchronously or asynchronously. TwinCAT supports all widespread field buses - even simultaneously if necessary. Thus, Beckhoff Lightbus, Profibus DP, Interbus, CANopen, DeviceNet, ControlNet, Modbus, Sercos, RS485/232, Ethernet TCP/IP and USB with a series of master and slave interfaces are currently supported. The PC peripherals (parallel and serial interfaces) and third-party interface cards are becoming available.
The System Manager allows a link between server process images and I/O channels in a bit-by-bit fashion and provides tools that consecutively connect 100 channels, for example, with only one command. At the field bus and process image levels of the servers, commissioning and