beckhoff TC170x — 4 Limitations

Limitations 4 Limitations | Limitations The TwinCAT 3 Usermode Runtime provides an execution environment for the same program code that is executed in the real-time runtime. The TwinCAT 3 Usermode Runtime has no guaranteed deterministic execution properties. The operating system is able to interrupt the Usermode Runtime at any time. The TwinCAT 3 Usermode Runtime can execute tasks with a minimum base time of 1 ms. ◦From version 4026.25 (package version 1.25.2): If any tasks are configured to run faster than 1 ms, that task is set to 1 ms, and all other tasks are executed at the original ratio (i.e., correspondingly slower). The TwinCAT 3 Usermode Runtime has no access to EtherCAT.

The I/O part of the configuration is therefore normally "disabled". Components that are based on the real-time Ethernet driver can be executed. The execution times and the jitter can affect the function due to the principle. CCAT-based network cards cannot be used. From version 4026.25 (package version 1.25.2): TwinCAT 3 Usermode Runtime can now access USB, which means, for example, that the license key USB stick can be used. In principle, it does not make sense to use all TwinCAT functions under a TwinCAT 3 Usermode Runtime. For example, some TwinCAT functions require a constant real-time tick. If appropriate, TwinCAT 3 functions are extended to work with the TwinCAT 3 Usermode Runtime.

In particular, if something has to be observed for the TwinCAT 3 Usermode Runtime with regard to the configuration, this is documented for the respective products. The execution order between the tasks may differ from the behavior in the real-time runtime due to the principle [ } 11] . For this reason, it also makes sense not to make the execution order dependent on the task priorities. NOTICE Use the TwinCAT 3 Usermode Runtime exclusively with TwinCAT 3.1 Build 4026 Enabling XAE Build 4024 or 4022 (including via Remote Manager) may result in unpredictable behavior but is not technically prevented.

The TwinCAT 3 Usermode Runtime is a feature of TwinCAT 3.1 Build 4026 and should only be used with that version to avoid system crashes, for example. TC170x 10 Version: 1.6.1