Technical introduction | Integration TwinCAT Functions The following aspects must be taken into account: The AmsNetIds ( command line parameter "-i") [ } 16] must be unique in an entire AMS network. This means that the TwinCAT 3 Usermode Runtimes must have different AmsNetIds. You must specify different configuration folders (using the "-c" command-line parameter [ } 16] ). This is typically done by copying the template from Program Files (x86). It is not possible to connect several TwinCAT 3 Usermode Runtimes from one system to another external system, as the router on the external system cannot distinguish between the TwinCAT 3 Usermode Runtimes.
In such a scenario, ADS-over-MQTT with a broker as intermediary should be evaluated. 5.8 Integration TwinCAT Functions | Integration TwinCAT Functions TwinCAT Functions must be partially upgraded to work with the TwinCAT 3 Usermode Runtime. The information required to commission the functions with the TwinCAT 3 Usermode Runtime is provided here. 5.8.1 TF5100 | TwinCAT 3 NCI (GST interpreter) | TF5100 | TwinCAT 3 NCI (GST interpreter) The TF5100 TwinCAT 3 NCI function is partially supported (GST interpreter, PLC interpolation) by the TwinCAT 3 Usermode Runtime. The Classic interpreter is not supported. GST interpreter Each Usermode Runtime instance has its own registry: TcRegistry.xml.
This defines the default directories for the GST interpreter. If the TcRegistry.xml file needs to be edited, the associated Usermode Runtime instance must not be started. C:\ProgramData\Beckhoff\TwinCAT\Mc\Nci\ Value> C: \ProgramData\Beckhoff\TwinCAT\Mc\Nci\UmRT_Default\ GST interpreter and Fast As Possible mode The GST interpreter is an ADS server outside the runtime in the Windows context. This means that the state of the GST interpreter is not taken into account when the cycle tick is presented in the Fast As Possible modes of the Usermode Runtime. This can result in the NC executing the Motion commands faster than the interpreter sends the commands to the NC.
This results in unrealistic dynamic progressions and a lack of smoothing. To prevent this, when using the Fast As Possible mode in conjunction with the GST interpreter, the lookahead of the NC should be monitored and switched to cyclic mode if the value falls below a threshold so that the interpreter has the chance to fill the lookahead again.
IF fbSetRtMode.bExecute = FALSE THEN IF io_X.NcToPlc.SafEntries > nSafEntriesThreshold THEN IF fbSetRtMode.rtMode E_RtMode.RtMode_FastAsPossible THEN fbSetRtMode.rtMode := E_RtMode.RtMode_FastAsPossible; fbSetRtMode.bExecute := TRUE; END_IF ELSIF fbSetRtMode.rtMode E_RtMode.RtMode_Cyclic THEN fbSetRtMode.rtMode := E_RtMode.RtMode_Cyclic; TC170x 14 Version: 1.6.1