Technical introduction | Integration TwinCAT Functions fbSetRtMode.bExecute := TRUE; END_IF ELSIF NOT fbSetRtMode.bBusy THEN fbSetRtMode.bExecute := FALSE; END_IF fbSetRtMode(); 5.8.2 TF6310 | TwinCAT 3 TCP/IP | TF6310 | TwinCAT 3 TCP/IP The function TF6310 TwinCAT 3 TCP/IP is based on an ADS Server, which is started by the TwinCAT 3 Usermode Runtime. To do this - after the function has been installed - a StartManConfig.xml file with the following content must be created in the 3.1\Target directory of the Usermode Runtime (for example:
C:\ProgramData\Beckhoff\TwinCAT\3.1\Runtimes\UmRT_Default\3.1\Target ) TcpIpServer C:\Program Files (x86)\Beckhoff\TwinCAT\Functions\TF6310-TCP-IP\Win32\Server\TcpIpServer.exe 5.8.3 TF7xxx | TwinCAT 3 Vision | TF7xxx | TwinCAT 3 Vision A few configurations must be taken into account to use TwinCAT 3 Vision with the Usermode Runtime. These are described in the TwinCAT 3 Vision documentation in the chapter Using the TwinCAT 3 Usermode Runtime . TC170x 15 Version: 1.6.1