Reference | Command line parameters & commands 6 Reference | Reference 6.1 Command line parameters & commands | Command line parameters & commands The TwinCAT 3 Usermode Runtime is implemented by the program TcSystemServiceUm.exe . This program can also be called up or used directly, which is why parameters and commands are described here. Parameter -i: Specifies the AmsNetId to be used. Example "-i 192.168.4.1.1.1" -n: Name of the TwinCAT 3 Usermode Runtime. Example "-n MyUmRuntime" -c: Path to the configuration folder. Example "-c ..\3.1" -f : Default 0x4 - Also enables execution as External Control [ } 13] or Fast As Possible [ } 13] . Legacy Mode (default up to version 1.18.3): 0x8.
Commands If the TwinCAT 3 Usermode Runtime is started on the command line, the following output appears: "c" switches to Config mode "r" switches to Run mode "s" queries the current state "x" exits the TwinCAT 3 Usermode Runtime 6.2 Configuration | Configuration The entire configuration of the TwinCAT 3 Usermode Runtime is carried out in the \3.1 directory. The structure of the directories is described at File storage [ } 11] . Here you will find the usual files that are also used for the real-time runtime. On the one hand, this concerns the boot directory, which contains the program to be executed by enabling a configuration.
On the other hand, the target directory, which for example also contains the route information via StaticRoutes.xml for the Usermode Runtime. Under Windows, TwinCAT saves a number of settings in the system-wide Windows registry. Because the Usermode Runtime may have different settings than the real-time runtime, the TcRegistry.xml file is provided locally in the \3.1 directory for this purpose. TC170x 16 Version: 1.6.1