beckhoff TE132x — 5.1.6 Bode Plot - Set properties

Configuration | Bode Plot Velocity (dp/dt directly from primary feedback): executes a Bode Plot for the velocity interface. (AX5000 only) Velocity (secondary feedback): executes a Bode Plot for the velocity interface. The actual values of the secondary (external) encoder are used for this. (AX5000 only) Position (NC interface without oversampling): executes a Bode Plot for the position. Velocity (NC interface without oversampling): executes a Bode Plot for the velocity. Torque (NC interface without oversampling): executes a Bode Plot on the torque (or current). The following settings are shown or hidden, depending on the mode: Position Monitoring Window [°]:

defines a window that is monitored during the Bode Plot. The object must not leave this window. The unit actually set is read out and the number is interpreted in accordance with the unit. Position Signal Amplitude [°]: this is where you set the amplitude of the excitation signal. Velocity Amplitude Scaling Mode: scales the signal amplitude during recording so that movements are not too large as the frequency increases. The following are available: Constant: the amplitude corresponds to the parameterized signal amplitude and remains constant over the entire frequency range. 1 / X at 1000Hz: scales the amplitude so that at 1000 Hz it has fallen to 1 / X of the start amplitude of 1 Hz (~1/f).

Useful ratios in practice are 1/5, 1/10 and 1/20. Torque Amplitude Offset: specifies an offset for the torque amplitude [in %]. Torque Amplitude Scaling Mode: scales the signal amplitude during the recording, depending on the current frequency. The following are available: Autoscale: scales the amplitude so that it is somewhat higher than the noise at a standstill. Constant: the signal amplitude remains the same over the entire frequency range. The amplitude 100 means 100% of the maximum current. Torque Signal Amplitude: represents the amplitude of the signal (or measurement) oscillation at 1 Hz (see Torque Amplitude Scaling Mode).

The unit of measurement is to be taken from the system settings (e.g. Drive, NC, etc.) and cannot be specified here. Velocity Base Amplitude: sets the amplitude of the basic oscillation (~1 Hz) for overcoming the static friction. The unit of measurement is to be taken from the system settings (e.g. Drive, NC, etc.) and cannot be specified here. Velocity Signal Amplitude: represents the amplitude of the signal (or measurement) oscillation at 1 Hz (see Velocity Amplitude Scaling Mode). The unit of measurement is to be taken from the system settings (e.g. Drive, NC, etc.) and cannot be specified here. Calculation Integral Time [s]: this is read during the plot.

It is the integral time of the controller that is set on the drive. Proportional Gain: the proportional gain can be used to achieve the desired performance. Expert Base Frequency: shows the frequency [in Hz] of the basic oscillation for overcoming the static friction (in the velocity modes only). Check Drive Limitations: If you want to check via the axes, you can specify this here. Current Maximum: displays the maximum current utilization [in %] of the recording. Current Mean: displays the average current utilization [in %] of the recording. Dead Time [s]: Indicates the complete dead time in seconds. Maximum Steps per Response:

sets the number of measuring points per system response for broadband excitations (e.g. MultiSine, Chirp, PRBS). Measure Sample Count: indicates the number of setpoint values and actual values from which an interpolation point of the Bode characteristic curve (a frequency point) is calculated. Measure System Dead Time: Indicates whether the system's dead time was measured with this recording, i.e., whether setpoints were copied to actual values. TE132x 27 Version: 1.3.0