Configuration | Bode Plot Measure Time: indicates the length of time [in s] for which the system is excited with one frequency. Setting Time: displays the duration [in s] during which the system settles to the current excitation. Signal Generator: displays the excitation type of the signal generator used. Smoothing: smoothing of the image using a moving average. The original data are retained here. Smoothing Diameter: diameter of the moving average in frequency points. Smoothing Max Frequency [Hz]: upper limit for smoothing. Only frequency points below this value are converted. Smoothing Min Frequency [Hz]: Lower limit for smoothing. Only frequency points above this value are converted.
User Dead Time [s]: displays the system's configured dead time. Velocity Amplitude Offset [°/s]: displays the offset used for the excitation amplitude. Target Cycle Time: Indicates the last-used cycle time [in ms]. Oversampling: indicates the oversampling factor to be used. If set to Suggested, the highest useful factor is automatically selected when the recording is started. Filter Set The special settings for Filter Sets are represented as follows: Filter Type: the type of filter can be set here. The other properties can be edited, depending on the selection. The following are available: Lowpass 1st Order: first-order low-pass filter. Lowpass 2nd Order:
second-order low-pass filter Phase Correction 1st Order: first-order phase correction element. 2nd-Order Phase Correction: second-order phase correction element. Notch: notch filter. High-Pass Damping: high-pass damping factor. TE132x 28 Version: 1.3.0