SOFTWARE SOFTWARE 9. Programming using the KUAX 671 PG 9.2. The operating modes for the KUAX 671 PG hand terminal: 9.1. General The limited operating mode The KUAX 671 PG hand terminal together with the KUAX 671 cam controller represent a single operating unit. All the parameters required to This is always started automatically whenever the supply voltage is applied. You can leave this operating mode only by entering a numerical access code, which must be entered via the button marked with the key. generate programs can be entered via the terminal. ‘The cam controller must be initialized before you start programming.
It is necessary to specify the number of pulses which the absolute angle encoder generates for each revolution of the shaft as otherwise the bit pattern in the data will not be interpreted correctly. This will cause the KUAX 671 system to malfunction. The zero point for the encoder can also be determined by using the hand terminal; mechanical adjustment is unnecessary. In this limited operating mode it is possible to select a program, however, so thatthe machine operator can stat the required cam programs at any time (cf.ch. 9.3.). Itis also possible to check the cam switching points while in this operating mode.
The desired cam must be specified by entering the program number and the output number. Up to eight programs can be written for each cam controller. When utilized tothe betta maximum (32 outputs, 1000 pulses per revolution) a total of The machine program cannot be modified while in this operating mode; this eliminates the possibility of inadvertently changing the contents ofa Program. 128.000 cams are theoretically possible. Neither is it possible to initialize the cam controller (for initial commissioning) while in this operating mode. The access code is set at 000 at the factory.
The open operating mode This operating mode is made accessible by entering the numerical code via the button marked with the key. This operating mode is indicated at the terminal with the message "PROGRAMMING MODE". Alll the functions required for initialization and program generation are accessible when in this operating mode. A change from one program to another is, of course, still possible. Display bright ness control Leave the open operating mode by depressing first the button marked with the key and then the button labelled "F’. ‘The operating functions and all their details are described on the following pages. The appropriate displays are shown as well. 31 32