TESTS OPERATION INDICATORS SOFTWARE 10. Using a personal computer to generate programs AND MALFUNCTION 11. Operation and malfunction indicators , General 11.1. Self-test on an Itis also possible to write programs for the KUAX 671 cam controller IBM personal computer (with MS-DOS operating system) or a compatible computer. A menu-type program is used to assist the operator. The documentation is on a project disk or hard disk respectively. The program may also be printed as instruction list or diagram. ‘The cam controller itself need not actually be present to generate the cam simulation programs. The program is transferred to the cam controller via the V.24 interface and an adapter. routine.
This is ‘The KUAX 671 hand terminal is equipped with a self-test L The display, the keypad and the 3 function. called up with the CTR program memory in the hand terminal are tested during this routine. ‘The display test is carried out first; it is completely automatic. Then follows the keypad test. The user must depress all the buttons once, in series, from the top left to the bottom right. The row and column of each button will be shown in the display. Detailed instructions for use are included with the software. ‘The RAM test will run automatically once the keypad test has been finished. Here the blocks which have been checked are shown in the display. Cf. ch. 13.3. for the order no. 11.2.
Malfunction indicators The KUAX 671 cam controller is equipped with three indicator LEDs to signal malfunctions with the following meanings: 11.2.1. RUN indicator (green LED) The green LED lights up to indicate the "control running” status. Tt goes out if one of the following malfunctions occurs: - No voltage supply to the cam controller. - Short circuit at the outputs. 49 51