Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4003A PRESSURIZING (Microwave tubes) 1. Purpose. The purpose of this test is to determine: a. Whether the input or output seals of the tube are capable of forming a leak-tight seal to their connectors, when the operating voltage or power level of the tube is such as to require operation with pressurized input or output. b. Whether the tube is physically damaged under the specified pressure. 2. Equipment. Use a suitable pressure chamber with appropriate flanging and pressure gauge. When waveguide connections are to be tested, the waveguide itself shall be the test chamber.
Potential leakage areas shall be painted with a soap solution. 3. Procedure. Pressurizing shall be performed by one of the following specified methods: 3.1 Method A, leakage. a. The chamber, together with the appropriate flanging and pressure gauge, shall be such that a specified differential air pressure shall be maintained for the specified duration, normally 2 minutes. (See note.) b. Leaks may be detected by painting potential leakage areas with a soap solution. 3.2 Method B, rate of leakage. The chamber shall be such as to maintain, as a minimum, the rate of leakage specified on the TSS (see note). 4. Acceptance criteria.
The leakage rate, when specified, shall not be exceeded and on completion of the test, the tube shall show no signs of physical damage and shall pass the specified tests. 5. Precautions. a. Care should be taken to ensure that the tube body temperature does not significantly affect the differential air pressure. NOTE: Where the waveguide connections are to be tested, the waveguide itself shall be the test chamber. b. Care shall be taken to ensure that no corrosive residue is left on the tube. METHOD 4003A 4003-1 25 March 1970