Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4006 X-RADIATION (Microwave tubes) 1. Purpose. To obtain the x-radiation intensity of microwave tubes in order to determine the levels emitted by the tubes when they are operated at high voltages with integral tube shielding in place but without external shielding. 2. Equipment. aperture for entrance of ionizing radiation shall have an area no larger than 10 cm 2 . The sensitivity of the detector at the wavelength (hardness) to be measured shall be known. The time constant shall be long enough to smooth out fluctuations in readings at low levels (usually 15 seconds). 2.1 Survey meter.
A dose-rate survey meter (electrostatically shielded) for probing or rapid surveying of radiation field. The 2.2 Film holder. A holder for x-ray sensitive film which has been designed to shield the film from exposure to light (and heat, if necessary). 2.3 Test equipment. To provide normal operation of the tube. 3. Procedure. 3.1 Method A (survey meter). A warm-up period shall be provided for both the tube and test equipment in order to obtain stable operating conditions before proceeding with measurements. 3.1.1 The background radiation shall be noted at the test position and corrections to the observed data shall be applied as required.
3.1.2 The TUT shall be in a position relative to the test equipment so that measurements will be made at the points where maximum radiation is observed. The tube shall be operated as specified in the TSS. 3.1.3 The detectors specified for this measurement are to be calibrated to read radiation level at the center of the detecting chamber. The distance from any readily accessible surface of the TUT to the center of the chamber shall be 12 inches or as specified in the TSS. 3.1.4 Readings. At the point of maximum radiation, record the maximum stable radiation observed in mR/hr. The maximum allowable radiation limit in mR/hr shall be specified on the TSS. 3.1.5 Calibration.
3.1.5.1 The survey meter shall be calibrated by exposure to sources which bracket the intensity and energy to be measured. The standard source(s) shall be traceable to the National Bureau of Standards. 3.1.5.2 Calibration shall be made using a minimum of three readings, which shall be averaged, for each point of calibration. 3.1.5.3 To insure accurate instrumentation, consideration shall be given to correction factors for extreme variations in temperature and barometric pressure. 3.1.5.4 Stability of the calibration shall be checked periodically by using an appropriate radioactive source. 3.2 Method B (film survey). 3.2.2 The tube shall be operated in accordance with the TSS.
Operation used is continued for the length of time specified for the film being used. 3.2.1 The film shall be positioned at a distance of 12 inches, or as specified, from readily accessible surfaces of the TUT. METHOD 4006 4006-1 13 September 1972