Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4229 REFLECTOR CURRENT (Reflex klystrons) 1. Purpose. The purpose of this test is to determine leakage and gas ion currents to the reflector electrode of a reflex klystron. 2. Definitions. 2.1 Total reflector current is the gas ion plus leakage current to the reflector electrode when the reflector electrode is operated as the ion collector of an ionization gauge. 2.2 Reflector-leakage current is the current to the reflector electrode when the tube is operated as in 2.1 except, that the beam current is interrupted by opening the cathode circuit.

2.3 Reflector-gas current is the remainder when 2.2 is subtracted from 2.1. 3. Equipment. 3.1 Power supplies are required to provide heater voltage, an accelerating voltage, and a retarding voltage as specified on the TSS. 3.2 A direct current meter is required which has sufficient sensitivity to measure the currents, which are normally less than 5 A dc. (A push-to-read circuit and a multiple range meter are recommended.) 4. Procedures. 4.1 Total reflector current. When specified voltages are applied to the tube, the total reflector current shall be within the limit(s) specified.

The duration of this test, including preheating time at specified test conditions if continuous with the test, shall be as specified. Unless otherwise specified, the tube should not be oscillating during this test. 4.2 Reflector-leakage current. At the conclusion of the test specified in 4.1, the cathode connection shall be opened and the reflector current shall be measured. 4.3 Reflector-gas current. When specified on the TSS, the value of current as determined in 4.2, shall be subtracted from the value of current as determined in 4.1. METHOD 4229 4229-1 19 April 1968