Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 5. Precautions. 5.1 The dynamic tuning rates used in the measurement shall be low enough that the time traversing any signal component shall exceed the response time of the measuring system. 5.2 When tuning dynamically and sweeping dynamically, the two rates shall be asynchronous so that all possible combinations of variables are encountered. METHOD 4243A 25 March 1970 4243-3