Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 When heat losses from the load and from the cooling liquid are not negligible, the calibration of the calorimeter shall take these losses into account by the following method: Set a liquid flow rate m1 grams/sec, and determine apparent power P1 from equation (1) above. Adjust the flow to a different rate m2 (about half or twice m1 is convenient) and determine apparent power P2. If P1 = P2, there is no significant cooling error. If P1 P2, the true power P is given by: 1 ) 2 1 ( 1 m m m P P ) 2 1 ( 2 m m m P 2 or: (m1-m2) log P = m1 log P1-m2 log P2.

P P m P P m K From a pair of readings, a general correction factor K(m) for any flow rate can be plotted using the equation: 2 1 ) ( ) ( m m m m m ) 2 1 ( 2 1 Where: P(m) is the apparent power at flow m. Alternatively, the relationship between temperature rise and power dissipated can be determined experimentally by substituting known values of dc or 60 Hz power in the calorimeter system. 4. Test B (bolometer method of average power measurement. The bolometer is a power detecting device whose operating resistance changes as a function of rf power dissipated across it.

The barretter is a bolometer using a noble metal which exhibits a positive temperature coefficient and the thermistor is a bolometer using a semiconductor which exhibits a negative temperature coefficient. 4.1 Test circuit. FIGURE 4250-4. Bolometer method. 4.2 Procedure. Using the circuit shown on figure 4250-4, the bolometer and bridge circuits are energized and the power to be measured is fed to the input of the bolometer mount. Care shall be taken to insure the time constant of the bolometer will not introduce error when making measurements of low-duty pulsed rf power. The thermistor with a time constant of 1 second is ideal for measurement of low-duty cycle rf power.

Also, when self-balancing bridges are used, care shall be taken to insure the pulse repetition rate does not adversely affect the automatic balancing. 5. Test C (comparison method of average power measurement). 5.1 Test circuit. FIGURE 4250-5. Comparison method. METHOD 4250A 4250-3 25 March 1970