Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4260 NOISE FIGURE (Microwave amplifier tubes) 1. Purpose. The purpose of this test is to measure thermal noise figure. 2. Method A (signal source method). 2.1 Test circuit. FIGURE 4260-1. Signal source method. 2.2 Procedure. Normal operating voltages are applied to the tube. With the input terminated, note the power output and attenuator setting. Increase the output attenuator 3 dB. Apply rf drive necessary to restore output power to previous indication. NF dB = 114-S-B Where:

NF = Noise figure in dB B = 10 log (BW in MHz of filter or measuring device, whichever is narrower) S = the power input from the calibrated signal source in dBm 2.3 Precautions. 2.3.1 The noise power from the TUT at the detector input should be much greater than the intrinsic detected noise. This can be ascertained by observing the noise power with the tube turned off and on. If there is not at least a 10 dB difference, the measured noise figure must be corrected by measuring the noise figure of the detector in the same way. Then the noise figure of the tube is given by:

receiver measured tube G NF NF NF 1 ) ( ) ( ) ( tube The noise figures and gain of the tube (G tube ) are in numerics; not dB. 2.3.2 The signal source shall present the source impedance for which the amplifier is designed. 2.3.3 The signal source shall be matched when it is on and when it is off. 2.3.4 Insure that spurious oscillations are not included in the measurement. METHOD 4260 19 April 1968 4260-1