Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4274A VOLTAGE TUNING RANGE 1. Purpose. The purpose of this test is to measure the voltage(s) required at the tuning element (electrode) to obtain an indicated frequency (or frequency range). 2. Definitions. a. Hole. A break in the voltage-frequency characteristic which, in effect, makes certain frequencies inaccessible. This break is the result of electronic tuning hysteresis and is measured in terms of the width of the inaccessible frequency band, F. b. Power drop-outs.

A power drop-out is a discontinuity in the power-frequency characteristic which exceeds a specified change in power, P, or which results in a reduction of power to a level which is less than specified minimum, P min. 3. Equipment. FIGURE 4274-1. Equipment layout for voltage tuning measurements. An oscilloscope with a fast enough response to observe power versus frequency, including any frequency discontinuity while sweeping the tube is required. Any frequency of operation can be found by observing the wavemeter pip on the oscilloscope. The regulation of the supplies shall be sufficient to stay within specified tolerances of the voltages and currents. 4. Procedure. a. Anode tuning (VTM).

With the specified conditions applied to all other electrodes, the anode voltage shall be adjusted to sweep the required frequency range. b. Delay line tuning (MBWO). With the specified conditions applied to all other electrodes, the delay line voltage shall be adjusted to sweep the required frequency range. c. Sole tuning (MBWO). With the specified conditions applied to all other electrodes, the sole voltage shall be adjusted to sweep the required frequency range. d. Ratio (slope) tuning (MBWO). With the specified conditions applied to all other electrodes, both the delay line voltage and sole voltage shall be adjusted to sweep the required frequency range.

The ratio of delay line voltage to sole voltage shall be maintained at the specified value. 5. Acceptance criteria. The tube shall tune the specified frequency range as a consequence of the specified voltage variations. The TSS shall specify the maximum value of F for holes, and P or P min for power drop-outs, or may require no detectable holes using a specified wavemeter. METHOD 4274A 25 March 1970 4274-1