Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4275 CONTROL ELECTRODE CHARACTERISTICS 1. Purpose. The purpose of this test is to measure the change in output resulting from the application of specified voltages to the control electrode. 2. Equipment. FIGURE 4275-1. Equipment layout for control electrode characteristics measurements. 3. Procedure. a. Cutoff power ratio. (1) With voltages adjusted to the specified values, measure the power output. (2) Change the control electrode voltage to the indicated value for cut-off, and again measure the power output.
The power level under these conditions may be quite low, so it may be necessary to change power measuring devices to make this power measurement. Cutoff power ratio is the ratio of the two measured powers expressed in dB. b. Cutoff current ratio. (1) With voltages adjusted to the specified values, measure the current to the specified electrode. (2) Change the control electrode voltage to the indicated value for cutoff, and again measure the current. Cutoff current ratio is the ratio of the two measured currents, expressed in dB. c. Modulation.
With the specified conditions applied to all other electrodes, the control electrode voltage shall be varied as specified, and the variation of power output shall be measured. The ratio of the highest and lowest values, expressed in dB, shall be within the limit(s) specified. METHOD 4275 4275-1 19 April 1968