Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4308A SPECTRUM 1. Purpose. The purpose of this test is to verify that the output of the tube is sufficiently well concentrated within a desired range of frequencies. The spectrum of a pulsed or modulated tube has the general appearance shown on figure 4308-1. For the purposes of this method, two parameters are defined: a. RF bandwidth. The width, in frequency units, of the spectrum at a level 6 dB below the peak; this includes any minor lobes which exceed the -6 dB level. b. Minor lobe ratio: The ratio of the major lobe amplitude to the highest minor lobe, normally expressed in dB. NOTE:
Measurement of either or both of these parameters may be specified. FIGURE 4308-1. RF spectrum, illustrating definitions of RF bandwidth and minor lobe ratio. 2. Test setup. The tube shall be operated in a mismatch unit and specified load; the VSWR of the unit shall be 1.5:1 (defined as in method 4310, pulling figure), variable over all phases (half wavelength motion of the mismatch). The TSS may specify the distance from the tube to the mismatch unit; if not, the unit shall be as close to the tube as is practicable. The output is sampled and fed to a spectrum analyzer, which will display a spectrum similar to figure 4308-1.
The mismatch phase is adjusted to the worst position for the parameter being measured (for example, either widest spectrum or highest side lobes). If the spectrum analyzer does not have adequate internal calibrators for frequency and amplitude, a marker generator may be used to provide frequency calibration points, and a calibrated attenuator may be inserted in the analyzer input line to measure minor lobe ratio as the difference in readings when the main lobe and highest minor lobe are brought in turn to a common reference level. 3. Calibration procedures for the load VSWR, spectrum analyzer, (and marker generator and attenuator if used) are standard, or as given by the manufacturers. 4.
Precautions. Since the spectrum of a tube is a sensitive function of the pulse shape or modulation delivered by the supply, as well as of the performance of the tube, care shall be taken to insure that the measurement of either RF bandwidth or minor lobe ratio is not degraded by poor performance of the modulator. NOTE: For short pulse measurements, the spectrum analyzer linearity shall be adequate to ensure that it does not degrade the bandwidth. This may be checked by varying the analyzer center frequency so as to shift the portion of the sweep used in the display, and observing that the spectrum shape does not change. 5. Formulas.
Since the theoretical minimum bandwidth is a function of the pulse duration, the TSS may specify the permissible bandwidth in terms of duration (for example, BW = 2.5/tp where BW is in MHz and tp in ms). In this case, the value to be used for tp is the measured value of the current pulse duration, tpc. METHOD 4308A 25 March 1970 4308-1