Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4309A MAGNETRON NONOSCILLATING IMPEDANCE 1. Purpose. To measure the impedance of a nonoscillating magnetron. 2. Definitions. a. Phase of sink. The phase of the sink is the position of a standing wave minimum (expressed in fractions of a guide wavelength), measured from the reference plane specified on the outline drawing, where the rate of change of oscillating frequency versus phase of the reflection coefficient is a maximum. It is measured positively in the direction away from the tube, toward the load.
With this phase of the reflection coefficient, power is generally maximum as well as instability and starting time jitter. b. Qo. The unloaded Q of the magnetron cavity system. 3. Measurement apparatus required. A microwave measurements system shall be assembled as indicated in the block diagram: FIGURE 4309-1. Magnetron nonoscillating impedance circuit. a. The signal generator shall be capable of smooth adjustment of the CW signal frequency as fine as 10 percent of the pulling figure of the magnetron. b. The attenuator may be internal to the signal generator, or external. c. The frequency measuring device shall be capable of resolution to better than 10 percent of the TUT's pulling figure.
d. The standing-wave detector shall be capable of indicating the minimum position with suitable accuracy and shall form a part of the uniform transmission system as specified on the outline drawing or by designation of the output coupler. e. The standing-wave indicator shall be suitably calibrated for use at the anticipated signal levels. 4. Measurements. The following tests shall be performed as specified. 4.1 Determination of VSWR and position of minimum. With TUT nonoperative at room temperature, adjust the signal generator frequency to the value obtained previously with the tube operating under normal conditions.
Measure VSWR and the position of the minimum which is nearest the reference plane, relative to the reference plane. Divide this distance by the guide wavelength, as measured or calculated in the same units. The value of VSWR and the fraction of the distance smaller than a half-guide wavelength shall be within the limit(s) specified. METHOD 4309A 4309-1 25 March 1970