Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 4.2 Phase of sink. With the tube nonoperating and at room temperature, the standing-wave detector is used to determine the distance, d, of the nearest minimum in the standing-wave pattern to the reference plane of the tube with respect to which it is desired to determine the phase of sink. This position is expressed in terms of the guide-wave length g as a function of frequency where measurements are made at frequencies below and above the cold resonant frequency of the TUT. Plots similar to those shown on figure 4309-2 (overcoupled case) and figure 4309-3 (undercoupled case) are obtained.
(It is noted that measurements are not performed in the immediate vicinity of the tube resonant frequency owing to a rapid change of phase in this region and consequent difficulties in obtaining accurate measurements.) A sufficient number of points should be taken to insure that they are falling on the linear portion of the phase characteristic. The phase of sink is the phase at the point of cold resonant frequency of the straight line drawn through the points of measurement. a. In the case of a tunable tube, the measurement may be simplified as follows: The signal generator is tuned to the frequency, Fo, at which it is desired to determine the phase of frequency sink.
The tube is tuned to a frequency far away from Fo. The position of the nearest minimum in the standing-wave pattern, d, as explained above, defines the phase of frequency sink at Fo. b. The procedure is the same in both the undercoupled and overcoupled cases. FIGURE 4309-2. Phase of standing-wave minimum as a function of frequency (overcoupled case). METHOD 4309A 25 March 1970 4309-2