Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 FIGURE 4309-3. Phase of standing-wave minimum as a function of frequency (undercoupled case). 5. Precautions. a. The rapid changes in phase of the reflection coefficient with frequency render measurements inaccurate unless suitable isolation has been provided between the signal generator and the measurements system (enough to eliminate changes in the signal generator tuning curve derived from the magnetron or wavemeter resonances). After measuring frequency, the wavemeter should be completely detuned. b.

A CW signal generator has been specified because the transient response of the resonant system will cause errors unless pulse lengths at least a magnitude longer than 2Qo/F are used. If this condition can be realized in a pulsed system, greater ease and accuracy of measurement of VSWR will result but it will be necessary to make certain that the output frequency does not change during the pulse. METHOD 4309A 4309-3 25 March 1970