Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4411 (OBSOLESCENT) IGNITOR OSCILLATION (TR tubes) The tube shall be placed in the circuit as shown on figure 4411-1, or equivalent circuit. With the supply voltage adjusted to 800 V dc, the ignitor current shall be set by means of the variable resistor in series with the ignitor electrode. The minimum current that will prevent low-frequency relaxation oscillations shall be within the limit(s) specified on the TSS. The high-frequency oscillations cause no difficulties.
Relaxation oscillations are indicated on the oscilloscope trace when the current drops below the level of the high-frequency relaxation oscillations. FIGURE 4411-1. Ignitor oscillation circuit. METHOD 4411 19 April 1968 4411-1